- Depth
- 121 mm
- Width
- 22.5 mm
- Faults
- Cross-wire or short-circuit monitoring of the switch connections; Failure of door contacts to open or close; Failure of the safety relay to pull-in or drop-out; Fault on the input circuits or the relay control circuits of the safety monitoring module; Interruption of the switch connections
- Height
- 100 mm
- Notice
- Discontinued product
- Category
- 3
- Mounting
- Snaps onto standard DIN rail to EN 60715
- Pfh Value
- 1.00 x 10⁻⁷ /h
- Standards
- BG-GS-ET-14; BG-GS-ET-20; EN IEC 60204-1; EN IEC 60947-1; EN IEC 60947-5-1; EN IEC 60947-5-3; EN IEC 60947-5-5; EN IEC 62061; EN ISO 13849-1
- Emc Rating
- EMC-Directive
- Certificates
- cULus
- Gross Weight
- 240 g
- Mission Time
- 20 Year(s)
- Stop-Category
- 0
- Note (General)
- Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
- Number Of Leds
- 1
- Product Family
- Safety relay module
- Ripple Voltage
- 10 %
- Climatic Stress
- BG-GS-ET-14; EN 60068-2-3
- Frequency Range
- 50 Hz; 60 Hz
- Feedback Circuit
- Yes
- Housing Material
- Glass-fibre reinforced thermoplastic, ventilated
- Operating Voltage
- 24 VAC -15 % / +10 %24 VDC -10 % / +20 %
- Note (Isd -Faults)
- The following faults are registered by the safety monitoring modules and indicated by ISD.
- Ambient Temperature
- +0 ... +55 °C
- Degree Of Pollution
- 2
- Note (Applications)
- Guard system; Safety sensor
- Overvoltage Category
- III
- Restistance To Shock
- 30 g / 11 ms
- Thermal Test Current
- 6 A